Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 482
Filtrar
1.
Sensors (Basel) ; 24(7)2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38610423

RESUMO

Metamaterial components and antennas are based on the general understanding that an artificial structure composed of adequately designed and manufactured elementary cells or arrays has unusual resonance and propagation properties. Metamaterials exhibit equivalent values of the dielectric constant and magnetic permeability that are both negative simultaneously, in contrast with ordinary materials. Single elements, periodic, or quasi-periodic configurations can be suitable for a metamaterial response. In this paper, equivalent circuits for microwave propagation and resonance are compared, deriving a lumped element modeling complementary to those already available in the literature, with a particular focus on planar resonating devices and calculating the effective value for the dielectric constant and the magnetic permeability directly from experimental findings using the impedance (Z-parameters) notation.

2.
Chemosphere ; 352: 141486, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38367875

RESUMO

Soil contamination with chlordecone, an organochlorine pesticide, is causing serious health problems, affecting crop production and local livestock valorization in the French West Indies. In-situ chemical reduction (ISCR) processes for soil remediation have shown promise but need improvement in terms of time, cost and effective treatment, particularly for andosol soil types. Our study shows that a 10-min microwave treatment significantly reduces chlordecone concentrations (50-90%) in contaminated andosol and nitisol soils. Dry andosol soils show the highest removal yields and reach a higher final temperature (350 °C). Microwave treatment is in all cases more effective or at least as effective as 60 min of conventional heating at a target temperature of 200 °C. The thermal response of andosol and nitisol to microwave exposure is different, as the former is likely to undergo thermal runaway, reaching high temperatures in a short time, resulting in highly efficient thermal removal of chlordecone. These results encourage further scale-up, particularly for the treatment of andosol soils due to their strong microwave response.


Assuntos
Clordecona , Hidrocarbonetos Clorados , Inseticidas , Praguicidas , Poluentes do Solo , Clordecona/análise , Inseticidas/análise , Micro-Ondas , Poluentes do Solo/análise , Solo , Índias Ocidentais
3.
Eur Radiol ; 2024 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-38337071

RESUMO

OBJECTIVES: To study the relationship between the ablation range and applied energy of laser ablation (LA) and microwave ablation (MWA) in papillary thyroid microcarcinoma (PTMC). METHODS: A total of 201 PTMC patients were treated with LA (n = 102) or MWA (n = 99) with single-applicator fixed ablation. The ablation range was determined by contrast-enhanced ultrasound. The ratios of ablation volume, longitudinal diameter, and orthogonal diameter to ablation energy (RAV/E, RAL/E, RAO/E) were analyzed and compared between MWA and LA. The effects of PTMC characteristics and Hashimoto's thyroiditis (HT) on ablation efficiency were evaluated by linear regression. RESULTS: The RAV/E was 0.72 (0.65-0.84) mm3/J for MWA and 0.48 (0.39-0.54) mm3/J for LA. HT was significantly correlated with RAV/E of LA (coefficient = - 0.367, p < 0.0001). RAL/E did not differ significantly between MWA and LA (MWA 0.026 mm/J, LA 0.025 mm/J; p = 0.957). However, MWA had a greater RAO/E than LA (MWA 0.014 mm/J, LA 0.012 mm/J; p < 0.0001). The plateau values of MWA and LA on the ablation orthogonal diameter were 10.7 mm and 8.69 mm, respectively. CONCLUSIONS: MWA showed a higher RAV/E than LA. More intuitively, MWA had a better ablation performance than LA on the orthogonal axis rather than the longitudinal axis. Theoretically, MWA and LA could achieve complete ablation of ≤ 6.70 mm and ≤ 4.69 mm PTMC separately by single-applicator fixed ablation considering a unilateral 2-mm safe margin. HT had a negative effect on LA but not on MWA. CLINICAL RELEVANCE STATEMENT: This study establishes strong connections between ablation energy and ablation range in papillary thyroid microcarcinoma (PTMC) in vivo, possibly contributing to the supplementation of the PTMC Ablation Consensus or Guidelines and providing a scientific basis for choosing clinical ablation parameters in PTMC. KEY POINTS: • Both microwave ablation (MWA) and laser ablation (LA) have excellent performance on the ablation longitudinal axis (easily exceeding 10 mm) for papillary thyroid microcarcinoma (PTMC). • MWA performed much better than LA on the ablation orthogonal axis. • MWA and LA are expected to achieve complete ablation of ≤ 6.70 mm and ≤ 4.69 mm PTMC separately by single-applicator fixed ablation considering a unilateral 2-mm safe margin.

4.
Antioxidants (Basel) ; 13(2)2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38397837

RESUMO

Carotenoids are ubiquitous and versatile isoprenoid compounds. The intake of foods rich in these pigments is often associated with health benefits, attributable to the provitamin A activity of some of them and different mechanisms. The importance of carotenoids and their derivatives for the production of foods and health-promotion through the diet is beyond doubt. In the new circular economy paradigm, the recovery of carotenoids in the biorefinery process is highly desirable, for which greener processes and solvents are being advocated for, considering the many studies being conducted at the laboratory scale. This review summarizes information on different extraction technologies (ultrasound, microwaves, pulsed electric fields, pressurized liquid extraction, sub- and supercritical fluid extraction, and enzyme-assisted extraction) and green solvents (ethyl lactate, 2-methyltetrahydrofuran, natural deep eutectic solvents, and ionic liquids), which are potential substitutes for more toxic and less environmentally friendly solvents. Additionally, it discusses the results of the latest studies on the sustainable green extraction of carotenoids. The conclusions drawn from the review indicate that while laboratory results are often promising, the scalability to real industrial scenarios poses a significant challenge. Furthermore, incorporating life cycle assessment analyses is crucial for a comprehensive evaluation of the sustainability of innovative extraction processes compared to industry-standard methods.

5.
Food Chem ; 443: 138568, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38301564

RESUMO

Previous studies showed that transglutaminase (TGase) and microwaves acted synergistically to improve the functional properties of proteins. The mechanism behind this has yet to be elucidated. In this study, the phenomenon of microwaves enhancing TGase activity was experimentally validated. Molecular docking and molecular dynamics simulations revealed that moderate microwaves (105 and 108 V/m) increased the structural flexibility of TGase and promoted the orientation of the side chain carboxylate anion group on Asp255, driving the reaction forward. Also, TGase underwent partial transformation from α-helix to turns or coils at 105 and 108 V/m, exposing more residues in the active site and facilitating the binding of the substrate (CBZ-Gln-Gly) to TGase. However, 109 V/m microwaves completely destroyed the TGase structure, inactivating the enzyme. This study provides insights into the molecular mechanisms underlying the interactions between TGase and substrate subjected to microwaves, promoting the future applications of TGase and microwaves in food processing.


Assuntos
Simulação de Dinâmica Molecular , Transglutaminases , Transglutaminases/metabolismo , Simulação de Acoplamento Molecular , Micro-Ondas , Proteínas
6.
Endocrinol Metab (Seoul) ; 39(1): 40-46, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38347707

RESUMO

Thyroid radiofrequency ablation and microwave ablation are widely adopted minimally invasive treatments for diverse thyroid conditions worldwide. Fundamental skills such as the trans-isthmic approach and the moving shot technique are crucial for performing thyroid ablation, and advanced techniques, including hydrodissection and vascular ablation, improve safety and efficacy and reduce complications. Given the learning curve associated with ultrasound-guided therapeutic procedures, operators need training and experience. While training models exist, limited attention has been given to ultrasound maneuvers in ablation needle manipulation. This article introduces two essential maneuvers, the zigzag moving technique and the alienate maneuver, while also reviewing the latest ultrasound techniques in thyroid ablation, contributing valuable insights into this evolving field.


Assuntos
Ablação por Radiofrequência , Nódulo da Glândula Tireoide , Humanos , Resultado do Tratamento , Nódulo da Glândula Tireoide/cirurgia , Ablação por Radiofrequência/métodos , Ultrassonografia
7.
Plants (Basel) ; 13(2)2024 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-38256706

RESUMO

Japanese knotweed (Reynoutria japonica Houtt.) is Poland's invasive weed, for which there is no efficient control method. The rhizomes of this species are rich in resveratrol. In this work, we evaluated (1) the effectiveness of electromagnetic microwaves (MV) in destroying Japanese knotweed using an original device, HOGWEED (MV of 2450 MHz), (2) the ecotoxic effect of the MV on the soil environment, and (3) the resveratrol content in knotweed rhizomes after MV treatment. The field studies were carried out in 2022 in southern Poland. Cut plants were MV-treated for times of 5.0-25.0 min. The MV efficiency was checked 10 and 56 days after treatment (DAT). After MV treatment, fresh soil samples were taken to analyze their ecotoxicity. As a result, at 56 DAT, knotweed was controlled if MV was used for at least 20.0 min. The MV did not affect the soil ecotoxicity. The MV-treated soils were classified as non-toxic or low-toxic. To analyze the resveratrol content, healthy knotweed rhizomes were dug out, treated with MV in the laboratory at 2.5-10.0 min, and analyzed for resveratrol content in HPLC-MS/MS. As a result, the resveratrol in the rhizomes significantly decreased in a time-dependent manner following MV exposure.

8.
Int J Hyperthermia ; 41(1): 2285705, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38269491

RESUMO

OBJECTIVE: The study aimed to compare the effectiveness and safety of ultrasound-guided microwave ablation (MWA) and percutaneous sclerotherapy (PS) for the treatment of large hepatic hemangioma (LHH). METHODS: This retrospective study included 96 patients who underwent MWA (n = 54) and PS (n = 42) as first-line treatment for LHH in three tertiary hospitals from January 2016 to December 2021. Primary outcomes were technique efficacy rate (volume reduction rate [VRR] > 50% at 12 months), symptom relief rate at 12 months and local tumor progression (LTP). Secondary outcomes included procedure time, major complications, treatment sessions, cost and one-, two-, three-year VRR. RESULTS: During a median follow-up of 36 months, the MWA group showed a higher technique efficacy rate (100% vs. 90.4%, p = .018) and symptom relief rate (100% vs. 80%, p = .123) than the PS group. The MWA group had fewer treatment sessions, higher one-, two- and three-year VRR, lower LTP rate (all p < .05), longer procedure time and higher treatment costs than the PS group (both p < .001). MWA shared a comparable major complications rate (1.8% vs. 2.4%, p = .432) with PS. After multivariate analysis, the lesion's heterogeneity and maximum diameter >8.1 cm were independent risk factors for LTP (all p < .05). In the PS group, lesions with a cumulative dose of bleomycin > 0.115 mg/cm3 had a lower risk of LTP (p = .006). CONCLUSIONS: Both MWA and PS treatments for large hepatic hemangioma are safe and effective, with MWA being superior in terms of efficacy.


Assuntos
Hemangioma , Neoplasias Hepáticas , Humanos , Escleroterapia , Micro-Ondas/uso terapêutico , Estudos Retrospectivos , Hemangioma/diagnóstico por imagem , Hemangioma/terapia , Neoplasias Hepáticas/terapia
9.
J Clin Monit Comput ; 38(1): 77-88, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37792139

RESUMO

PURPOSE: Non-contact continuous respiratory rate monitoring is preferred for early detection of patient deterioration. However, this technique is under development; a gold standard respiratory monitor has not been established. Therefore, this prospective observational method comparison study aimed to compare the measurement accuracy of a non-contact continuous respiratory rate monitor, a microwave Doppler sensor positioned beneath the mattress, with that of other monitors. METHODS: The respiratory rate of intensive care unit patients was simultaneously measured using a microwave Doppler sensor, capnography, thoracic impedance pneumography, and a piezoelectric sensor beneath the mattress. Bias and 95% limits of agreement between the respiratory rate measured using capnography (standard reference) and that measured using the other three methods were calculated using Bland-Altman analysis for repeated measures. Clarke error grid (CEG) analysis evaluated the sensor's ability to assist in correct clinical decision-making. RESULTS: Eighteen participants were included, and 2,307 data points were analyzed. The bias values (95% limits of agreement) of the microwave Doppler sensor, thoracic impedance pneumography, and piezoelectric sensor were 0.2 (- 4.8 to 5.2), 1.5 (- 4.4 to 7.4), and 0.4 (- 4.0 to 4.8) breaths per minute, respectively. Clinical decisions evaluated using CEG analyses were correct 98.1% of the time for the microwave Doppler sensor, which was similar to the performance of the other devices. CONCLUSION: The microwave Doppler sensor had a small bias but relatively low precision, similar to other devices. In CEG analyses, the risk of each monitor leading to inadequate clinical decision-making was low. TRIAL REGISTRATION NUMBER: UMIN000038900, February 1, 2020.


Assuntos
Micro-Ondas , Taxa Respiratória , Humanos , Reprodutibilidade dos Testes , Monitorização Fisiológica/métodos , Capnografia/métodos
10.
Eur Radiol ; 34(1): 236-246, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37505251

RESUMO

OBJECTIVES: To retrospectively evaluate the safety and efficacy of computed tomography (CT)-guided percutaneous microwave ablation in treating early-stage non-small cell lung cancer (NSCLC) adjacent to bronchovascular bundles. METHODS: Two hundred and thirty-one patients with early-stage NSCLC who underwent CT-guided microwave ablation of the tumor were included for analysis. Among these, 66 lesions were located adjacent to the bronchovascular bundle. Achievement of the specific ablation range (defined as the ablation zone encompassing the tumor and the adjacent vessel) was assessed after ablation. Complications and tumor progression after treatment were examined and compared between the bronchovascular bundle and non-bronchovascular bundle groups. RESULTS: A total of 231 patients were included. Overall, 1-, 2-, and 3-year local progression-free survival (LPFS) was 77.4%, 70.5%, and 63.8%, respectively. Bronchovascular bundle proximity, pure-solid tumor, tumor size, and ablation margin < 5 mm were independent risk factors for local progression in multivariate analysis. In the bronchovascular bundle group, the 1-, 2- and 3-year LPFS rates were 63.0%, 50.7%, and 43.4%, respectively; vessel proximity and specific ablation range failure were independent risk factors for local progression. Overall survival in the entire cohort was 93.0% at 1 year, 76.1% at 2 years, and 55.0% at 3 years. The incidence of postoperative complications did not significantly differ between the two groups (p > 0.05). The most common complication was pneumothorax. Severe hemoptysis did not occur. CONCLUSION: Tumor location near the bronchovascular bundles was a significant risk factor for local progression after microwave ablation. Achieving a specific ablation range may increase LPFS for these lesions. CLINICAL RELEVANCE STATEMENT: Achieving the specific ablation range may improve local efficacy for early-stage non-small cell lung cancer located adjacent to the bronchovascular bundle. KEY POINTS: • Local efficacy of percutaneous microwave ablation in treating early-stage non-small cell lung cancer was affected by bronchovascular bundle proximity. • Achieving the specific ablation range may improve local efficacy for lesions located adjacent to the bronchovascular bundle.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Ablação por Cateter , Neoplasias Pulmonares , Carcinoma de Pequenas Células do Pulmão , Humanos , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/cirurgia , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/cirurgia , Micro-Ondas/uso terapêutico , Estudos Retrospectivos , Ablação por Cateter/métodos , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
11.
Nanomaterials (Basel) ; 13(23)2023 Dec 03.
Artigo em Inglês | MEDLINE | ID: mdl-38063767

RESUMO

A new method for the synthesis and deposition of tungsten oxide nanopowders directly on the surface of a carbon-fiber-reinforced polymer composite (CFRP) is presented. The CFRP was chosen because this material has very good thermal and mechanical properties and chemical resistance. Also, CFRPs have low melting points and are transparent under ionized radiation. The synthesis is based on the direct interaction between high-power-density microwaves and metallic wires to generate a high-temperature plasma in an oxygen-containing atmosphere, which afterward condenses as metallic oxide nanoparticles on the CFRP. During microwave discharge, the value of the electronic temperature of the plasma, estimated from Boltzmann plots, reached up to 4 eV, and tungsten oxide crystals with a size between 5 nm and 100 nm were obtained. Transmission electron microscopy (TEM) analysis of the tungsten oxide nanoparticles showed they were single crystals without any extended defects. Scanning electron microscopy (SEM) analysis showed that the surface of the CFRP sample does not degrade during microwave plasma deposition. The X-ray attenuation of CFRP samples covered with tungsten oxide nanopowder layers of 2 µm and 21 µm thickness was measured. The X-ray attenuation analysis indicated that the thin film with 2 µm thickness attenuated 10% of the photon flux with 20 to 29 KeV of energy, while the sample with 21 µm thickness attenuated 60% of the photon flux.

12.
Materials (Basel) ; 16(23)2023 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-38068095

RESUMO

Currently, in the context of biorefinery and bioeconomy, lignocellulosic biomass is increasingly used to produce biofuels, biochemicals and other value-added products. Microwaves and ultrasound are emerging techniques that enable efficient and environmentally sustainable routes in the transformation of lignocellulosic biomass. This review presents some of the most important works published in the last few years on the application of microwaves and/or ultrasound in lignocellulosic materials pretreatment and can be used as a starting point for research into this theme. This review is divided into four parts. In Part I, the theoretical fundamentals of microwave and ultrasound treatments are reviewed. Dielectric constants for biomass, factors that influence pretreatment, are some of the subjects addressed. In Part II, the effects that these techniques have on lignocellulosic biomass (on the size and surface area of the particle; on the content of lignin, hemicellulose and cellulose; on the crystallinity index of cellulose; on the effect of solubilization of organic matter; on hydrolysis and reduction of sugars) are discussed. In Part III, emphasis is given to the contribution of microwaves and ultrasound in obtaining value-added products. In this context, several examples of liquefaction and extraction procedures are presented. Part IV describes examples of performing sonocatalysis on lignocellulosic biomass to obtain value-added products, such as furfural, whose production is significantly reduced by ultrasound treatment.

13.
Eur Radiol ; 2023 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-38114848

RESUMO

OBJECTIVES: To evaluate the safety and efficacy of microwave ablation (MWA) for stage I non-small cell lung cancer (NSCLC) in patients with idiopathic pulmonary fibrosis (IPF). MATERIALS AND METHODS: A retrospective single-center cohort study was conducted in patients with clinical stage I NSCLC who underwent CT-guided MWA from Nov 2016 to Oct 2021. The patients were divided into the IPF group and the non-IPF group. The primary endpoints were 90-day adverse events and hospital length of stay (HLOS). The secondary endpoints included overall survival (OS) and progression-free survival (PFS). RESULTS: A total of 107 patients (27 with IPF and 80 without IPF) were finally included for analysis. No procedure-related acute exacerbation of IPF or death occurred post-MWA. The rates of adverse events were similar between the groups (48.6% vs. 47.7%; p = 0.998). The incidence of grade 3 adverse events in the IPF group was higher than that in the non-IPF group without a significant difference (13.5% vs. 4.6%; p = 0.123). Median HLOS was 5 days in both groups without a significant difference (p = 0.078). The 1-year and 3-year OS were 85.2%/51.6% in the IPF group, and 97.5%/86.4% in the non-IPF group. The survival of patients with IPF was significantly poorer than the survival of patients without IPF (p < 0.001). There was no significant difference for PFS (p = 0.271). CONCLUSION: MWA was feasible in the treatment of stage I NSCLC in patients with IPF. IPF had an adverse effect on the survival of stage I NSCLC treated with MWA. CLINICAL RELEVANCE STATEMENT: CT-guided microwave ablation is a well-tolerated and effective potential alternative treatment for stage I non-small cell lung cancer in patients with idiopathic pulmonary fibrosis. KEY POINTS: • Microwave ablation for stage I non-small cell lung cancer was well-tolerated without procedure-related acute exacerbation of idiopathic pulmonary fibrosis and death in patients with idiopathic pulmonary fibrosis. • No differences were observed in the incidence of adverse events between patients with idiopathic pulmonary fibrosis and those without idiopathic pulmonary fibrosis after microwave ablation (48.6% vs. 47.7%; p = 0.998). • The 1-year and 3-year overall survival rates (85.2%/51.6%) in the idiopathic pulmonary fibrosis group were worse than those in the non- idiopathic pulmonary fibrosis group (97.5%/86.4%) (p < 0.001).

14.
Eur Radiol Exp ; 7(1): 67, 2023 11 07.
Artigo em Inglês | MEDLINE | ID: mdl-37932631

RESUMO

BACKGROUND: Malignant tumors routinely present with irregular shapes and complex configurations. The lack of customization to individual tumor shapes and standardization of procedures limits the success and application of thermal ablation. METHODS: We introduced an automated treatment model consisting of (i) trajectory and ablation profile planning, (ii) ablation probe insertion, (iii) dynamic energy delivery (including robotically driven control of the energy source power and location over time, according to a treatment plan bespoke to the tumor shape), and (iv) quantitative ablation margin verification. We used a microwave ablation system and a liver phantom (acrylamide polymer with a thermochromic ink) to mimic coagulation and measure the ablation volume. We estimated the ablation width as a function of power and velocity following a probabilistic model. Four representative shapes of liver tumors < 5 cm were selected from two publicly available databases. The ablated specimens were cut along the ablation probe axis and photographed. The shape of the ablated volume was extracted using a color-based segmentation method. RESULTS: The uncertainty (standard deviation) of the ablation width increased with increasing power by ± 0.03 mm (95% credible interval [0.02, 0.043]) per watt increase in power and by ± 0.85 mm (95% credible interval [0, 2.5]) per mm/s increase in velocity. Continuous ablation along a straight-line trajectory resulted in elongated rotationally symmetric ablation shapes. Simultaneous regulation of the power and/or translation velocity allowed to modulate the ablation width at specific locations. CONCLUSIONS: This study offers the proof-of-principle of the dynamic energy delivery system using ablation shapes from clinical cases of malignant liver tumors. RELEVANCE STATEMENT: The proposed automated treatment model could favor the customization and standardization of thermal ablation for complex tumor shapes. KEY POINTS: • Current thermal ablation systems are limited to ellipsoidal or spherical shapes. • Dynamic energy delivery produces elongated rotationally symmetric ablation shapes with varying widths. • For complex tumor shapes, multiple customized ablation shapes could be combined.


Assuntos
Técnicas de Ablação , Neoplasias Hepáticas , Humanos , Micro-Ondas/uso terapêutico , Técnicas de Ablação/métodos , Modelos Teóricos
15.
Eur Radiol ; 2023 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-37938388

RESUMO

OBJECTIVE: To evaluate the efficacy and safety of microwave ablation (MWA) for the treatment of symptomatic benign thyroid nodules in children. METHODS: A retrospective study of MWA for the treatment of 34 symptomatic benign thyroid nodules in 25 children was conducted. Volume reduction ratio (VRR), technique efficacy, symptom score, cosmetic score, and thyroid function were used to evaluate the efficacy of the technique. The associated complications and side effects were recorded. RESULTS: The participants were followed for at least 6 months (median 12 months, range 6-48 months). After MWA treatment, the volumes of the targeted nodules decreased gradually (median volume 5.86 mL before MWA and 0.34 mL at the final follow-up assessment), the VRR achieved was up to 85.03% at the final follow-up assessment, and the technical efficacy at this time was 91.2%. The subjective and objective nodule-related symptoms were also ameliorated. The circulating hormone concentrations reflecting thyroid function remained within their normal ranges in all the participants after one month of follow-up. The procedure had no major complications. CONCLUSIONS: MWA seems to be an effective and safe technique for the treatment of symptomatic benign thyroid nodules in pediatric patients. CLINICAL RELEVANCE STATEMENT: Microwave ablation is a safe and effective method to treat symptomatic benign thyroid nodules in pediatric patients. This treatment may be selected if the patient or parents are not suitable or refuse to undergo surgery. KEY POINTS: • Microwave ablation is effective in reducing the volume of benign thyroid nodules and ameliorating nodule-related symptoms in pediatric patients. • Microwave ablation is a safe method in children, with low complications. • Microwave ablation does not affect the circulating thyroid hormone concentrations of children.

16.
Eur Radiol ; 2023 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-37926741

RESUMO

OBJECTIVES: The experience of thermal ablation of lung lesions is limited, especially performing the procedure under localisation by cone-beam CT in the hybrid operation room (HOR). Here, we present the experience of microwave ablation (MWA) of lung nodules in the HOR. METHODS: We reviewed patients who underwent image-guide percutaneous MWA for lung nodules in the HOR under general anaesthesia between July 2020 and July 2022. The workflow in the HOR including the pre-procedure preparation, anaesthesia consideration, operation methods, and postoperative care was clearly described. RESULTS: Forty lesions in 33 patients who underwent MWA under general anaesthesia (GA) in the HOR were analysed. Twenty-seven patients had a single pulmonary nodule, and the remaining six patients had multiple nodules. The median procedure time was 41.0 min, and the median ablation time per lesion was 6.75 min. The median global operation room time was 115.0 min. The median total dose area product was 14881 µGym2. The median ablation volume was 111.6 cm3. All patients were discharged from the hospital with a median postoperative stay of 1 day. Four patients had pneumothorax, two patients had pleural effusion during the first month of outpatient follow-up, and one patient reported intercostal neuralgia during the 3-month follow-up. CONCLUSIONS: Thermal ablation of pulmonary nodules under GA in the HOR can be performed safely and efficiently if we follow the workflow provided. The procedure provides an alternative to managing pulmonary nodules in patients. CLINICAL RELEVANCE STATEMENT: Thermal ablation of pulmonary nodules under GA in the HOR can be performed safely and efficiently if the provided workflow is followed. KEY POINTS: • We tested the feasibility of microwave ablation of lung lesions performed in a hybrid operating room. • To this end, we provide a description of microwave ablation of the lung under cone-beam CT localisation. • We describe a workflow by which ablation of the pulmonary nodule can be performed safely under general anaesthesia.

17.
Nanotechnology ; 35(3)2023 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-37852228

RESUMO

Electromagnetic fields can penetrate aqueous media in a homogeneous and instantaneous way, without physical contact, independently of its temperature, pressure, agitation degree and without modifying their chemical compositions nor heat and mass transfer conditions. In addition, superparamagnetic biomaterials can interact with electromagnetic fields by absorbing electromagnetic energy and transforming it in localized heat with further diffusion to surrounding media. This paper is devoted to the exploration of the potential use of hyperthermic effects resulting from the interaction between externally applied electromagnetic fields and superparamagnetic nanoparticles as a trigger for controlled drug release in soft tissue simulating materials. Gelatin based soft tissue simulating materials were prepared and doped with superparamagnetic nanoparticles. The materials were irradiated with externally applied electromagnetic fields. The effects on temperature and diffusion of a drug model in water and phosphate buffer were investigated. Significant hyperthermic effects were observed. The temperature of the soft tissue simulating material resulted increased from 35 °C to 45 °C at 2.5 °C min-1. Moreover, the release of an entrapped model drug reached 89%. The intensity of the hyperthermic effects was found to have a strong dependency on the concentration of superparamagnetic nanoparticles and the power and the pulse frequency of the electromagnetic field.


Assuntos
Sistemas de Liberação de Medicamentos , Nanopartículas , Sistemas de Liberação de Medicamentos/métodos , Campos Eletromagnéticos , Temperatura Alta , Temperatura , Nanopartículas/química
18.
Eur Radiol ; 2023 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-37875593

RESUMO

OBJECTIVES: The study of postoperative liver decompensation after microwave ablation (MWA) for hepatocellular carcinoma (HCC) in patients with clinically significant portal hypertension (CSPH) is still lacking. The purpose of the present study was to compare the postoperative liver decompensation after MWA and laparoscopic resection (LR) for HCC in patients with CSPH. METHODS: The present retrospective study enrolled 222 HCC patients with CSPH who underwent MWA (n = 67) or LR (n = 155). Postoperative liver decompensation, complications, postoperative hospital stays, and overall survival were analyzed. Factors associated with postoperative liver decompensation were identified. RESULTS: After propensity score matching, the postoperative liver decompensation rate was significantly lower in the MWA group than that in the LR group (15.5% versus 32.8%, p = 0.030). The multivariable regression analysis identified that type of treatment (MWA vs. LR, odds ratio [OR] 0.44; 95% confidence interval [CI], 0.21-0.91; p = 0.026) and Child-Pugh B (OR, 2.86; 95% CI, 1.24-6.61; p = 0.014) were independent predictors for postoperative liver decompensation. The rate of complications for patients in the MWA group was significantly lower than that in the LR group (p < 0.001). And MWA showed shorter postoperative hospital stays than LR (3 days vs. 6 days, p < 0.001). Overall survival rate between the two groups was not significantly different (p = 0.163). CONCLUSION: Compared with laparoscopic resection, microwave ablation has a lower rate of postoperative liver decompensation and might be a better option for HCC patients with CSPH. CLINICAL RELEVANCE STATEMENT: Microwave ablation exhibited a lower incidence of postoperative liver decompensation in comparison to laparoscopic resection, thereby conferring greater advantages to hepatocellular carcinoma patients with clinically significant portal hypertension. KEY POINTS: •Postoperative liver decompensation rate after microwave ablation was lower than that of laparoscopic resection for hepatocellular carcinoma in patients with clinically significant portal hypertension. •Microwave ablation showed shorter postoperative hospital stays than laparoscopic resection. •Microwave ablation had fewer complications than laparoscopic resection.

19.
Front Surg ; 10: 1255929, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37795145

RESUMO

Objectives: To compare the usefulness and safety of off-clamp microwave scissors-based sutureless partial nephrectomy (MSPN) with on-clamp conventional partial nephrectomy (cPN) in dogs. Methods: We performed off-clamp MSPN using microwave scissors (MWS) in six dogs, and on-clamp cPN in three dogs, in two-stage experiments. The bilateral kidney upper poles were resected via a midline incision under general anesthesia. After 14 days of follow-up, the lower pole resections were performed. The renal calyces exposed during renal resections were sealed and transected using MWS in off-clamp MSPN and were sutured in on-clamp cPN. In the off-clamp MSPN group, the generator's power output of MWS was set as either 50 W or 60 W for each kidney side. We compared the procedure time (PT), ischemic time (IT), blood loss (BL), and normal nephron loss (NNL) between the two techniques using the Mann-Whitney U-test. Results: We successfully performed 24 off-clamp MSPNs and 12 on-clamp cPNs. The off-clamp MSPN was significantly superior to on-clamp cPN in avoiding renal ischemia (median IT, 0 min vs. 8.6 min, p < 0.001) and reducing PT (median PT, 5.8 min vs. 11.5 min, p < 0.001) and NNL (median NNL, 5.3 mm vs. 6.0 mm, p = 0.006) with comparable BL (median BL, 20.9 ml vs. 23.2 ml, p = 0.804). No bleeding and major urine leakage were noted during the reoperations. Conclusions: Off-clamp MSPN outperforms on-clamp cPN in lowering the risks of postoperative renal function impairment in dogs.

20.
ChemSusChem ; : e202301200, 2023 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-37672358

RESUMO

This paper reports a new sustainable protocol for the microwave-assisted catalytic conversion of levulinic acid into N-substituted pyrrolidones over tailor-made mono (Pd, Au) or bimetallic (PdAu) catalysts supported on either highly mesoporous silica (HMS) or titania-doped HMS, exploiting the advantages of dielectric heating. MW-assisted reductive aminations of levulinic acid with several amines were first optimized in batch mode under hydrogen pressure (5 bar) in solvent-free conditions. Good-to-excellent yields were recorded at 150 °C in 90 min over the PdTiHMS and PdAuTiHMS, that proved recyclable and almost completely stable after six reaction cycles. Aiming to scale-up this protocol, a MW-assisted flow reactor was used in combination with different green solvents. Cyclopentyl methyl ether (CPME) provided a 99 % yield of N-(4-methoxyphenyl) pyrrolidin-2-one at 150 °C over PdTiHMS. The described MW-assisted flow synthesis proves to be a safe procedure suitable for further industrial applications, while averting the use of toxic organic solvents.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...